Special offer
Accumulation tank (without coils) KHT EAM-C-00 1000
Accumulation tank (without coils) KHT EAM-C-00 1000

CHF1,030.68

Regular price: CHF1,515.91

Lowest price in the last 30 days: CHF1,030.68
pcs
Accumulation tank (without coils) KHT EAM-C-00 1500
Accumulation tank (without coils) KHT EAM-C-00 1500

CHF1,294.32

Regular price: CHF1,902.50

Lowest price in the last 30 days: CHF1,294.32
pcs
Accumulation tank (without coils) KHT EAM-C-00 2000
Accumulation tank (without coils) KHT EAM-C-00 2000

CHF1,767.05

Regular price: CHF2,598.86

Lowest price in the last 30 days: CHF1,767.05
pcs
Accumulation tank (without coils) KHT EAM-C-00 500
Accumulation tank (without coils) KHT EAM-C-00 500

CHF651.14

Regular price: CHF956.82

Lowest price in the last 30 days: CHF651.14
pcs
Accumulation tank (without coils) KHT EAM-C-00 750
Accumulation tank (without coils) KHT EAM-C-00 750

CHF883.86

Regular price: CHF1,300.23

Lowest price in the last 30 days: CHF883.86
pcs
Product of the Day
Kocioł Stalmark EKO VEGAS 22 kW z podajnikiem po prawej stronie
Kocioł Stalmark EKO VEGAS 22 kW z podajnikiem po prawej stronie

CHF3,511.36

Regular price: CHF4,386.36

Lowest price in the last 30 days: CHF3,511.36
pcs
Kocioł Stalmark EKO VEGAS 22 kW z podajnikiem po lewej stronie
Kocioł Stalmark EKO VEGAS 22 kW z podajnikiem po lewej stronie

CHF3,511.36

Regular price: CHF4,386.36

Lowest price in the last 30 days: CHF3,511.36
pcs
IMPORTANT INFORMATION

Important Information

Overview of essential installation requirements, safety guidelines, and component descriptions for proper boiler operation.

1. Circulation System – Open or Closed?

Open System: Requires an open expansion vessel mounted at the highest point. The vessel should accommodate 5–10% of the total system volume. Example setup shown below.

Closed System: Requires a pressurized expansion vessel (5–10% capacity). Must include at least one safety valve:

  • 1.5 bar for boilers up to 65 kW
  • 2 bar for boilers above 65 kW

To prevent overheating, a cooling device is required. Two common solutions:

a) Cooling Circuit with One-Way Valve

Activates above 97°C to cool the entire system. Built-in for some models (e.g. Atmos, Orlan Super), optional for others (Dakon Dor, Ogniwo 12.6–20kW). Required for other steel/cast iron boilers along with a thermal release valve (e.g. Danfoss BVTS, Watts STS-20).

b) Two-Way Thermal Release Valve

Injects cold water and removes hot water simultaneously. Used in larger boilers (>50 kW). Must be positioned so its sensor touches moving hot water (activation: 95–97°C). Examples: Regulus DBV-1, Syr 5067, Caleffi 544.

2. Equipment

To ensure proper combustion, boilers may include:

  • Draught Regulator: Mechanically adjusts air inlet according to target temperature
  • Ventilator: Blows air into the combustion chamber, usually electronically controlled

Check the product page for what's included or optional.

3. Boiler with Automatic Fuel Feeder

Ideal for user comfort. Automatically fed retort burner provides optimal fuel combustion and clean exhaust. Simply refill the hopper every 3–10 days. Compatible with coal (5–25 mm screw feeders) or fine coal (piston feeders).

4. Mixing Valves

Three-way mixing valve: Installed at the return pipe to prevent corrosion by raising return water temperature. Can be manual or thermostatic. Ports 1 & 3 always allow circulation; Port 2 opens with rising temperature.

Three-way valve illustration

Four-way mixing valve: Offers return temperature protection and radiator temperature control by redirecting some hot water back to the boiler and returning some cooled water to the radiators.

Four-way valve system

5. Non-Warranty Components

Ceramic parts, cast iron components, sealing cords, and insulation materials are considered consumable parts and are not covered under warranty.