Wood Gasifying Boiler ATTACK DPX

The ATTACK DPX boiler is a wood gasifying boiler from the 6000 series. It is designed for burning wood, making the boiler very user-friendly. The gasifying boiler is eco-friendly, offering high-quality construction and excellent efficiency. The larger loading chamber saves time needed for continuous refueling. Heating with the DPX boiler provides high comfort and long life. This boiler is a versatile solution for efficient biomass combustion, resulting in high efficiency. There is an option to choose the boiler version with the loading door opening to the right or left side. The DPX15 version does not have flue gas turbulators, so the boiler needs manual cleaning.

Warranty for ATTACK boilers:

  • 24 months
  • 36 months if installed with a buffer tank and Laddomat charging unit

Long Burning Time

With full utilization of the loading chamber, the fuel in the boiler will burn continuously for 8-12 hours, depending on the boiler's power. Pieces of wood with a length of 1.2 meters only need to be cut in half because of the extra-large loading chamber, allowing much larger pieces of wood to be used.

 

Automatic Flue Damper

The DPX boiler features an automatic flue damper for igniting and adding wood. The damper ensures direct exhaust of flue gases from the loading chamber to the chimney and facilitates easier boiler ignition. Opening the loading doors activates the damper, and it automatically closes after closing the doors, eliminating the need for manual operation.

Wood Boiler and its Quality

The DPX gasifying boiler, like all ATTACK products, is manufactured using high-quality materials and appropriate technological solutions, such as 6mm thick boiler steel, movable turbulators, and refractory fittings up to 1350°C. All of this guarantees the high quality of the boiler's construction.

Attack gasifying boiler

Higher Boiler Power and Control Options

The wood gasifying boiler DPX is equipped with the PROFI regulation. Boiler control is straightforward and intuitive, with each regulation having different properties. Of course, the boiler includes automatic shutdown after fuel burning, automatic cleaning, control of heating pumps, and charging the accumulation tank. For achieving higher boiler power, we recommend purchasing an accumulation tank together with a Laddomat mixing device.

Attack burner

PROFI Boiler Regulation

If there is a need to control a larger number of devices, it is worth opting for a boiler with PROFI control. The PROFI-type control utilizes a more precise PID regulator, allowing for more efficient parameter regulation. This results in a more precise and smooth regulation of the fan speed, thereby improving control over flue gas temperature, which affects the final boiler efficiency. In addition to the PID regulation for better combustion efficiency, the Fuzzy Logic technology contributes by using sensors to monitor combustion and adjust the process in real-time for optimizing efficiency. The PROFI control system enables the handling of complex heating systems. It offers the option to control the charging pump of the accumulation tank, domestic hot water, or the circulation pump. The presented system also manages the accumulation tank and prevents its depletion, shutting down the boiler if there is insufficient fuel. The PROFI regulation is straightforward and intuitive to use. The display shows all the necessary operational information (boiler temperature, flue gas temperature, accumulation tank temperature) and the current status of individual elements (fan operation, charging pump for DHW / accumulation tank, circulation pump operation).

PROFI Control Features

  • Suitable for everyday heating
  • PID regulator - more precise and smooth regulation of fan speed
  • Fuzzy Logic control sensors
  • Controls 2 pumps (circulation pump + charging pump for the accumulation tank or DHW)
  • For solutions with the accumulation tank - built-in logic for charging and protection against tank depletion
  • Easy operation and display showing current operational information (boiler temperature, flue gas temperature, accumulation tank temperature)
  • Monitoring of parameters (fan operation, charging pump for DHW / accumulation tank, circulation pump operation)
  • Control of the circulation pump with a thermostat
  • Automatic boiler shutdown after fuel burning
  • Manual setting of primary and secondary air
Attack Slovak boiler

Boiler Structure and Cross-section

Attack cross-section
 

Technical Data

Parameter DPX15 DPX25 DPX30 DPX35 DPX40 DPX45 DPX80 DPX100
Nominal Power (STANDARD version) [kW] 15 25 30 35 40 45 80 100
Power Range (PROFI version) [kW] 7.5-15 12.5-25 15-30 17.5-35 20-40 22.5-45 32-80 40-100
Heat Exchanger Surface [m2] 1.98 2.52 2.78 3.03 5.60
Charging Chamber Volume [dm3] 82 125 158 190 440
Charging Door Dimensions [mm] 235×445 292×542
Required Chimney Draft [Pa] 23 35
Max. Water Pressure in the Boiler [kPa] 250
Water Pressure Loss on the Water Side (T 10K) [kPa] 1.9 2.3 4.4 6.6 2.1
Water Pressure Loss on the Water Side (T 20K) [kPa] 0.6 0.7 1 1.8 0.55
Boiler Weight [kg] 370 430 460 490 800
Chimney Connection [mm] 150 200
Height [mm] 1240 1575
Width [mm] 700 915
Depth [mm] 840 1240 1340 1440 1890
Charging Chamber Depth [mm] 400 590 690 790 1100
Protection Degree [IP] 21
Electric Power Consumption [W] 32 38 48 54 78 90
Boiler Efficiency [%] 91.3 90.4 90.1 90.2 86.5 87
Boiler Class [-] 5
Flue Gas Temperature at Nominal Power [°C] 160 165 170 180 170 180 204 205
Flue Gas Flow Rate at Nominal Power [kg/s] 0.014 0.018 0.020 0.022 0.025 0.028 0.045 0.050
Max. Noise Level [dB] 65
Fuel [-] Dry wood with calorific value of 15-17 MJ/kg, moisture content min. 12% - max. 20%, Φ 80-150 mm
Average Wood Consumption [kg/h] 3.9 6.5 7.8 9.1 10.4 11.75 21.5 26.8
Fuel Consumption per Season [-] 1 kW = 0.9 m3
Max. Wood Length [mm] 350 550 650 750 1000
Operating Hours at Maximum Performance [h] 3
Boiler Water Volume [L] 80 100 110 128 250
Required Accumulation Tank Capacity [L] 800 - 1500 1000 - 2500
Power Supply Voltage [V/Hz] ~230/50
Temperature Range of Heated Water [°C] 65-90

Technical data

Boiler class (303-5:2012) 5
Power output 15 kW
Exhaust gas pipe diameter 150 mm
Weight 370 kg
Ecodesign +
Height 1240 mm
Width 700 mm
Depth 840 mm
Producer's recommended minimum volume of accumulation tanks 800 - 1500 L
Flue gas temperature 160 °C
Mass flow 0,014 kg/s
Required chimney draught 23 Pa
Max. length of wood 350 mm
Silo volume 82 dm³
Loading compartment dimensions 235 x 445 mm