Manual fired boiler for coal PROSAT UNI 18 kW
Regular price:
product unavailable
add to wish list
Description
PROSAT UNI
The boiler from PROSAT company of UNI type is a boiler designed for heating water in a central heating system as well as for heating hot utility water. It is a boiler in which fuel to the combustion chamber is supplied manually through the hopper door. It uses the technique of bottom combustion of hard coal ensuring economical and clean fuel combustion.
To obtain optimal combustion conditions, regulation of the amount of incoming air is performed using the throttle of the lower doors, which regulation is manual or with the help of a draft gauge, throttle of the middle doors, as well as through secondary air throttles located on the side of the boiler. The boiler must be operated with a storage tank in order to meet the requirements of the PN-EN 303-5:2012 standard.
Advantages
- Heat exchanger made of certified boiler plate
- Primary fuel: hard coal
- High combustion efficiency and heat exchange: above 89%
- Compact boiler design
- Combustion chamber with ceramic catalysts
- Adapted for installation of thermostatic draft regulator
- Adjustable secondary air nozzle
Technical Data
| Technical Data | [Unit] | UNI 10 | UNI 13 | UNI 18 | UNI 24 |
| Nominal heat output | [kW] | 10 | 13 | 18 | 24 |
| Burn time | [h] | 4.5 | |||
| Boiler heating surface | [m2] | 1.3 | 1.7 | 2.4 | 3.2 |
| Boiler water capacity | [l] | 62 | 72 | 88 | 100 |
| Approximate size of heated area | [m2] | up to 120 | up to 160 | up to 220 | up to 280 |
| Boiler class according to PN-EN 303-5:2012 | [-] | ecodesign | |||
| Efficiency | [%] | 89 | |||
| Fuel chamber capacity | [dm3] | 24 | 28 | 36 | 48 |
| Max. supply temperature | [°C] | 85 | |||
| Min. supply temperature | [°C] | 55 | |||
| Average flue gas temperature | [°C] | 143 | 120 | 145 | |
| Max. water temperature supplying buffer tank | [°C] | 85 | |||
| Max. allowable working pressure | [Mpa] | 0.2 | |||
| Test pressure | [Mpa] | 0.35 | |||
| Required flue gas draft | [mbar] | 0.2 | 0.25 | ||
| Minimum buffer tank capacity | [L] | 600 | 800 | 1200 | 1600 |
| Min. chimney cross-section | [cm2] | 250 | 400 | ||
| Minimum chimney height | [m] | 6 | |||
| Flue spigot diameter | [mm] | 150 | 160 | ||
| Boiler weight | [kg] | 243 | 254 | 315 | 336 |
| Diameter of supply and return nozzle | [in] | 1 | 1 1/2 | ||
| Diameter of draft gauge nozzle | [in] | 3/4 | |||
| Noise emission | [dB] | < 30 | |||
| Height | [mm] | 1190 | 1230 | 1280 | |
| Width | [mm] | 455 | 595 | ||
| Depth | [mm] | 595 | 650 | 700 | |
Technical data
| Power output | 18 kW |
| Exhaust gas pipe diameter | 160 mm |
| Efficiency | 89 % |
| Ecodesign | + |
| Height | 1230 mm |
| Width | 595 mm |
| Depth | 650 mm |
| Minimum chimney section | 250 cm² |
| Outlet and inlet size | 1 1/2 G |
| Producer's recommended minimum volume of accumulation tanks | 1200 L |

All reviews (positive and negative) are displayed. We don't verify that they come from customers who have purchased the product.