Joule Cyclone Tank in Tank ECO 500 L ErP C
Regular price:
DKK33,398.21
The promotion runs until 24 July 2026
product unavailable
add to wish list
Description
Joule Cyclone "Tank in Tank" ECO is a modern solution thanks to which we will obtain the fastest hot water recovery.
Tank in Tank ECO
Tanks can be used in heat pumps, fireplaces with water jackets, any solar systems and boiler types, etc. Cyclone tanks are insulated with fire resistant, hard and ecological polyurethane foam. The whole thing is covered with powder coated steel jacket. Both hot water tank and external one are made of DUPLEX stainless steel.
Advantages:
- Designed to work with solar collectors, heat pumps, fireplace with water jacket etc.
- Connection to low and high temperature heating circuit
- Both tanks and coil made of stainless steel

Dane techniczne :
| Type | 250L | 300L | 400L | 500L |
| Product code | TCTMVD-00250FC | TCTMVD-00300FC | TCTMVD-00400FC | TCTMVD-00500FC |
| Heating circuit capacity (l) | 150 | 175 | 235 | 300 |
| Storage capacity of the DHW cylinder (l) | 100 | 125 | 165 | 200 |
| Dimensions - width | 620 | 710 | ||
| Dimensions - height | 1400 | 1600 | 1900 | |
| Tank insulation thickness polyurethane hard foam (mm) | 50 | |||
| Heating surface of coil (m2) | 0,7 | |||
| Maximum operating temperature (heating) | 90 | |||
| Maximum operating pressure (central heating circuit) bar | 3 | |||
| Maximum operating pressure (hot water circulation) bar | 6 | |||
| Heating circuit pressure loss (mbar) | 40 | 42 | 45 | 47 |
| Parking losses (W) | 87 | 92 | 102 | 115 |
| Energy Class | C | |||
| HEAT WATER EXPENSES - heat source coil | 250L | 300L | 400L | 500L |
| Peak output at 40 C (L/30min) | 331 | 418 | 558 | 601 |
| Peak output 1 hour 40 C (L/60min) | 768 | 888 | 1184 | 1306 |
| Peak output at 45 C (L/30min) | 298 | 348 | 464 | 536 |
| Peak output 1 hour 45 C (L/60min) | 649 | 732 | 976 | 1078 |
| Peak output at 60 C (L/30min) | 175 | 206 | 274 | 316 |
| Peak output 1 hour 60 C (L/60min) | 358 | 402 | 536 | 589 |
| Heating time from cold state (min) | 72 | 75 | 95 | |
| CHARGE WATER EXPENSES - heat source boiler | 250L | 300L | 400L | 500L |
| Peak output at 40 C (L/30min) | 331 | 418 | 558 | 601 |
| Peak output 1 hour 40 C (L/60min) | 1103 | 1225 | 1633 | 1748 |
| Peak output at 45 C (L/30min) | 298 | 348 | 464 | 536 |
| Peak output 1 hour 45 C (L/60min) | 976 | 1003 | 1338 | 1459 |
| Peak output at 60 C (L/30min) | 175 | 206 | 274 | 316 |
| Peak output 1 hour 60 C (L/60min) | 556 | 590 | 786 | 886 |
| Heating time from cold state (min) | 39 | 45 | 55 | |

All reviews (positive and negative) are displayed. We don't verify that they come from customers who have purchased the product.