The boiler KOMFORT EKO LUX is a boiler from the Komfort Eko series, designed for installation in an open heating system, can be installed in a closed heating system, with a working pressure not exceeding 2.5 bar provided that thermal protection is used, e.g. DBV-2 cooling valve. System protection should meet the requirements of standards PN-EN-12828 and PN-EN 303-5.
The boiler KOMFORT EKO LUX has been equipped with an advanced K1Pv4 controller with a color touchscreen panel (additionally supports heating system components). It is possible to purchase a GSM or INTERNET module, which allows you to monitor the boiler outside the home.
The furnace also has an innovative solution, which is the ABM system, an energy-efficient geared motor (power consumption 30W) with high efficiency and auto-reverse in case of fuel feeder blockage.
The combustion chamber is equipped with an automatic retort burner. In the flue ducts there are economizers (flue gas swirlers), designed to increase boiler efficiency and reduce flue gas emission levels. Fuel for the combustion process is transported automatically from the fuel tank located nearby by means of an Archimedean screw feeder.
Flue gases are discharged to the chimney through a flue located in the rear or upper wall of the boiler (CG version). For loading purposes and periodic cleaning and maintenance, the boiler is equipped with closed and sealed combustion chamber and ash pan doors. Additionally, cleaning doors are placed in the front of the boiler - depending on the boiler power, single or double.
The fuel tank is equipped with a filler hatch with a sealed closing mechanism. It has a flap opening sensor, which protects against leaving the fuel tank cover open. To reduce heat loss, the external surface of the boiler is insulated from the environment using external cladding made of steel sheets, under which thermal insulation is placed made of asbestos-free mineral wool.
Boilers meet the energy and emission requirements of class 5 of the standard PN EN 303-5:2012 and have an Ecodesign Certificate.

Standard Equipment:
- K1Pv4 electronic controller,
- ADAPTIVE CONTROL steering,
- PID function,
- NZ version for closed system,
- blower fan (installation at own expense),
- boiler leveling foot (installation at own expense),
- fuel feed system with burner,
- fuel tank,
- analog thermometer,
- ash drawer,
- flue gas swirlers,
- ceramic deflector,
- ceramic linings of the combustion chamber.
Additional boiler equipment (for an additional fee):
- STRAŻAK I extinguishing system,
- STRAŻAK II extinguishing system,
- SPK LUX room controller,
- Additional mixing valve controller,
- GSM Module,
- WIFI internet module,
- DBV-2 cooling valve,
- SPK Lux wireless controller,
- wireless RS communication kit.
Functions implemented by the K1Pv4 controller:
- innovative ADAPTIVE CONTROL steering using a turbine flow meter ensuring optimal selection of fan and feeder operating parameters
- history of the last twenty boiler alarm states
- possibility of exporting temperature history to external USB memory
- possibility of cooperation with the extract fan module
- fan and Archimedean screw feeder control
- mixing valve actuator control as standard
- weekly control
- heating and hot water pump control
- control of two additional pumps
- possibility of connecting a room controller with RS communication or traditional e.g. SPK LUX
- possibility of connecting the DEFRO GSM module
- possibility of connecting a new version of the DEFRO Internet module enabling remote change of boiler operating parameters (access to user and service menu) via www.emodul.pl
- possibility of controlling two additional valves using DEFRO MZ modules
- support for geared motor with reverse operation (does not apply to PZ version)
- large, color graphic display
- touch panel
- adjustable display tilt angle in the range from 45° to 105°
- heating, hot water, valve, return, additional, flue gas and external temperature sensor
- temperature protection (thermal)
- screw feeder temperature sensor (protection)
The boiler heat exchanger was made of certified boiler steel with a thickness of 6 mm.
Energy-efficient high-efficiency geared motor with auto-reverse in case of fuel feeder blockage.
Combustion chamber with highly effective retort burner.
Fuel feeder screw made entirely from one element.
System equalizing pressure in the fuel tank.
The manufacturer provides a 5-year warranty on the heat exchanger tightness and a 2-year warranty on proper boiler operation and other components.
Vertical or horizontal flue configuration after installing a turning elbow (turning elbow is not part of the boiler equipment);
Boiler adapted as standard for installation in a closed system provided that installation is in accordance with the boiler DTR.
Ceramic catalysts stabilizing the combustion process.
Change of door opening direction (does not apply to internal incandescent doors).
Fuel tank cover opening sensor.
ADAPTIVE CONTROL steering - boiler operation regulation based on air flow through the heat exchanger.
K1P v4 controller with color touchscreen panel supporting 4 pumps (heating, hot water, circulation, floor). Mixing valve support. Possibility of control via GSM or INTERNET - additional paid option, adjustable angle of the control panel position.
High thermal efficiency reaching 90% thanks to increased heat recovery from flue gases.
Basic component elements of the DEFRO Komfort Eko LUX boiler

- steel body with thermal insulation;
- cleaning doors;
- combustion chamber doors;
- ash pan doors;
- supply nozzle;
- return nozzle;
- drain nozzle;
- flue;
- flue cleaning hatch (only in case of flue outlet in the rear wall);
- electronic controller;
- analog thermometer;
- fan;
- fuel feeder;
- geared motor;
- fuel tank;
- handle for carrying the fuel tank;
- fuel tank inspection opening;
- fuel feeder inspection opening;
- mounting sleeve of the feeder temperature sensor for the STRAŻAK I1) system;
- mounting nozzle of the BVTS valve of the STRAŻAK I1) system;
- mounting nozzle of the BVTS valve of the STRAŻAK II1) system;
- controller wire connection strip;
- cover plate of sensor mounting sleeves of the controller;
- cable pass-through;
- fuel tank air inlet connection;
- mounting sleeve of the flue gas sensor;
- STB temperature limiter;
- leveling feet for boilers;
- main switch;
- mounting sleeve of the return water temperature sensor.
1) STRAŻAK I and STRAŻAK II systems are not part of the boiler equipment, optional equipment for an additional fee.
| Boiler Name | Komfort Eko LUX | |||||||||||||||||||||||||||||||||||
| Specification/boiler type | U.m. | 12 | 15 | 20 | 25 | 30 | 40 | |||||||||||||||||||||||||||||
| Power range | kW | 3.6 - 12 | 4.5 - 15 | 6.0 - 20 | 7.5 - 25 | 9.0 - 30 |
| |||||||||||||||||||||||||||||
| Boiler class (303-5:2012) | 5 |
| Power output | 25 kW |
| Exhaust gas pipe diameter | 178 mm |
| Weight | 513 kg |
| Efficiency | 90.6 % |
| Ecodesign | + |
| Outlet and inlet size | 1 1/2 G |
| Warranty | 60 mies. |
| Min. chimney height | 7 m |
| Silo volume | 191 dm³ |
| Max working pressure | 1.5 bar |
| thickness of steel | 6 mm |
| Min. chimney diameter | 180 mm |
| Clean Air Program | + |