Automatic boiler Defro Komfort Eko LUX 12 kW with feeder on left side
Regular price:
93 709,09 Kč
The promotion runs until 24 July 2026
product unavailable
add to wish list
Description
The KOMFORT EKO LUX boiler is a boiler from the Komfort Eko series, designed for installation in an open heating system. It can be installed in a closed heating system with a working pressure not exceeding 2.5 bar, provided that thermal protection is applied, such as a DBV-2 cooling valve. Installation protections should meet the requirements of standards PN-EN-12828 and PN-EN 303-5.
The KOMFORT EKO LUX boiler has been equipped with an advanced K1Pv4 controller with a color touch panel (additionally handles heating installation components). It is possible to purchase a GSM or INTERNET module, which gives us remote control over the boiler outside the home.
The boiler also features an innovative solution in the form of the ABM system, an energy-saving geared motor (power consumption 30W) with high efficiency and auto-reverse in case of fuel feeder blockage.
The combustion chamber is equipped with an automatic retort burner. In the flue gas ducts are placed economizers (flue gas swirlers), designed to increase boiler efficiency and reduce flue gas emission levels. Fuel for the combustion process is transported automatically from the fuel tank located nearby using a screw conveyor.
Flue gases are discharged to the chimney through a flue outlet located in the rear or upper wall of the boiler (CG version). For loading purposes and periodic cleaning and maintenance, the boiler is equipped with closed and sealed furnace-ash pan doors. Additionally, cleaning doors are located on the front of the boiler - depending on the boiler output, single or double.
The fuel tank is equipped with a filling hatch with a sealed closing mechanism. It has a flap opening sensor, which protects against leaving the fuel tank cover open. To reduce heat loss, the external surface of the boiler is insulated from the surroundings using external steel sheet cladding, under which thermal insulation is placed made of asbestos-free mineral wool.
The boilers meet the energy and emission requirements of class 5 of the PN EN 303-5:2012 standard and have an Ecodesign Certificate.

Standard equipment:
- K1Pv4 electronic controller,
- ADAPTIVE CONTROL control,
- PID function,
- NZ version for closed system,
- blower fan (installation at your own discretion),
- boiler leveling foot (installation at your own discretion),
- fuel supply system with burner,
- fuel tank,
- analog thermometer,
- ash pan,
- flue gas swirlers,
- ceramic deflector,
- ceramic linings of the combustion chamber.
Additional boiler equipment (for an additional fee):
- FIREFIGHTER I extinguishing system,
- FIREFIGHTER II extinguishing system,
- SPK LUX room controller,
- Additional mixing valve controller,
- GSM module,
- WIFI internet module,
- DBV-2 cooling valve,
- SPK Lux wireless controller,
- RS wireless communication set.
Functions performed by the K1Pv4 controller:
- innovative ADAPTIVE CONTROL with turbine flow meter ensuring optimal selection of fan and feeder parameters
- history of the last twenty boiler alarm states
- ability to export temperature history to external USB memory
- ability to work with exhaust fan module
- fan and screw feeder control
- mixing valve actuator control as standard
- weekly control
- heating pump and hot water pump control
- control of two additional pumps
- ability to connect a room controller with RS communication or traditional such as SPK LUX
- ability to connect DEFRO GSM module
- ability to connect the new version of DEFRO Internet module enabling remote change of boiler parameters (access to user and service menus) via www.emodul.pl
- ability to control two additional valves using DEFRO MZ modules
- operation of a geared motor with reverse operation (does not apply to PZ version)
- large, color graphic display
- touch panel
- adjustable display tilt in the range from 45° to 105°
- heating, hot water, valve, return, additional, flue gas and external temperature sensors
- temperature protection (thermal switch)
- screw feeder temperature sensor (protection)
The boiler heat exchanger is made of certified boiler steel with a thickness of 6 mm.
Energy-saving geared motor with high efficiency and auto-reverse in case of fuel feeder blockage.
Combustion chamber with highly effective retort burner.
Fuel feeder screw made entirely from one element.
System equalizing pressure in the fuel tank.
The manufacturer provides a 5-year warranty on heat exchanger tightness and a 2-year warranty on proper boiler operation and other components.
Vertical or horizontal flue outlet configuration after mounting the swivel elbow (swivel elbow is not part of boiler equipment);
Boiler adapted as standard for installation in a closed system, provided that installation is in accordance with the boiler DTR.
Ceramic catalysts stabilizing the combustion process.
Change of door opening direction (does not apply to internal incandescent doors).
Fuel tank cover opening sensor.
ADAPTIVE CONTROL - boiler operation regulation based on air flow through the heat exchanger.
K1P v4 controller with color touch panel controlling 4 pumps (heating, hot water, circulation, floor heating). Mixing valve handling. Possibility of control via GSM or INTERNET - option paid separately, adjustable angle of the control panel position.
High thermal efficiency reaching 90% thanks to increased heat recovery from flue gases.
Basic component parts of the DEFRO Komfort Eko LUX boiler

- steel body with thermal insulation;
- cleaning doors;
- furnace doors;
- ash pan doors;
- supply port;
- return port;
- drain port;
- flue outlet;
- flue outlet cleaning (only in case of flue outlet in the rear wall);
- electronic controller;
- analog thermometer;
- fan;
- fuel feeder;
- geared motor;
- fuel tank;
- fuel tank carrying handle;
- fuel tank inspection opening;
- fuel feeder inspection opening;
- mounting sleeve for fuel feeder temperature sensor for FIREFIGHTER I system1);
- mounting port for BVTS valve of FIREFIGHTER I system1);
- mounting port for BVTS valve of FIREFIGHTER II system1);
- terminal strip for controller wire connections;
- covering for mounting sleeves of controller sensors;
- wire feedthrough;
- fuel tank air supply connection;
- mounting sleeve for flue gas sensor;
- STB temperature limiter;
- boiler leveling feet;
- main switch;
- mounting sleeve for return water temperature sensor.
1) FIREFIGHTER I and FIREFIGHTER II systems are not part of boiler equipment, optional equipment paid separately.
| Boiler Name | Komfort Eko LUX | ||||||||||||||||||||||||||||||||||
| Description/boiler type | Unit | 12 | 15 | 20 | 25 | 30 | 40 | ||||||||||||||||||||||||||||
| Power range | kW | 3.6 - 12 | 4.5 - 15 | 6.0 - 20 | 7.5 - 25 | 9.0 - 30 | 12.0 - 40 | ||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||
| Boiler class (303-5:2012) | 5 |
| Power output | 12 kW |
| Exhaust gas pipe diameter | 159 mm |
| Weight | 364 kg |
| Efficiency | 90.4 % |
| Ecodesign | + |
| Height | 1433 mm |
| Width | 1012 mm |
| Depth | 792 mm |
| Outlet and inlet size | 1 1/2 G |
| Warranty | 60 mies. |
| Min. chimney height | 5.5 m |
| Silo volume | 132 dm³ |
| Max working pressure | 1.5 bar |
| thickness of steel | 6 mm |
| Min. chimney diameter | 160 mm |
| Clean Air Program | + |

All reviews (positive and negative) are displayed. We don't verify that they come from customers who have purchased the product.