KHT THP-GP-PU Enamelled Heating Towers – Compact Combination Tanks for Heat Pumps
The KHT THP-GP-PU series heating towers are combination tanks designed for use with heat pumps. They integrate two units in a single casing: a central heating buffer tank and an enamelled domestic hot water (DHW) storage tank. This solution saves space in the boiler room, simplifies system installation and reduces the number of additional connections required.
The unit consists of two tanks housed within a shared casing. The upper tank is designed for heating and storing domestic hot water, while the lower tank serves as a buffer for the central heating system. Domestic hot water is heated by means of a coil that transfers heat from the heating circuit to the water stored in the upper tank.
The upper DHW tank is made of steel and coated with ceramic enamel. Magnesium anodes provide additional corrosion protection, with their weight and length depending on the selected model. The enamelled internal surface protects the tank used for domestic hot water storage.
The KHT THP-GP-PU heating towers are equipped with heating coils with a surface area of 2.4 m² in the 205/75 model and 3.2 m² in the 290/105 model. The heat exchanger output is 56 kW and 74 kW respectively, while the continuous output reaches 1400 l/h or 1800 l/h. This allows the appropriate version to be selected according to the requirements of the heating system.
The lower buffer tank stores heating water and provides an appropriate water volume in the central heating circuit. It is equipped with several heating water connections positioned at different heights, allowing it to be connected to the installation. The tanks also feature connections for installing electric heating elements.
The tank casing is fitted with rigid PU polyurethane foam thermal insulation. Combining the DHW storage tank and central heating buffer in one unit reduces the space required for installing individual components of the heating system.
Key advantages of KHT THP-GP-PU heating towers
- Combined design – an enamelled DHW storage tank and a lower central heating buffer integrated into one casing.
- Designed for heat pumps – the series is intended for use in heating systems equipped with heat pumps.
- Ceramic enamel – the internal surface of the upper tank is coated with enamel.
- Heat exchanger coil – transfers thermal energy to the domestic water stored in the upper tank.
- Magnesium anodes – provide additional corrosion protection for the enamelled tank.
- Lower central heating buffer – stores heating water and provides an appropriate water volume in the central heating system.
- PU thermal insulation – made of rigid polyurethane foam.
- Electric heating element connections – allow additional electric heating elements to be installed.
- High energy efficiency class – energy efficiency class A for both models.
- Space-saving design – two functions integrated into a single unit.
Construction and operating principle
The KHT THP-GP-PU heating tower consists of two tanks housed within a shared casing. The upper section is responsible for storing domestic hot water, while the lower section serves as a central heating buffer. This design combines both components of the installation in one unit.
Domestic hot water is heated by a coil located inside the upper tank. The heating medium flowing through the heat exchanger transfers thermal energy to the water stored inside. Depending on the model, the coil capacity is 15.2 l or 24 l, and its heat exchange surface area is 2.4 m² or 3.2 m² respectively.
The lower tank acts as a buffer, storing heating water. Connections positioned at different heights allow it to be integrated into the central heating circuit. Additional connections allow electric heating elements to be installed.
Corrosion protection and thermal insulation
The upper domestic hot water tank is made of steel and protected with ceramic enamel. Magnesium anodes provide additional corrosion protection. In the THP-205/75 model, their total weight is 0.9 kg, while in the THP-290/105 model it is 1.1 kg.
The thermal insulation is made of rigid PU polyurethane foam. It forms the external insulating layer of the tank and reduces heat loss.
Applications
KHT THP-GP-PU heating towers are primarily designed for heating systems operating with heat pumps. They are used in systems where both domestic hot water storage and heating water buffering are required.
Thanks to their integrated design, they can be installed in residential buildings and other properties equipped with central heating and domestic hot water systems. The availability of two versions makes it possible to select a model suited to the parameters and requirements of a particular installation.
Technical data – KHT THP-GP-PU

Connections and connection layout
| Technical data | Unit | THP-205/75 | THP-290/105 |
|---|---|---|---|
| Cold water inlet h1 / Drain pipe h7 | inch / mm | 1 / 556 | 1 / 558 |
| Circulation connection h2 | inch / mm | 3/4 / 1361 | 3/4 / 1363 |
| DHW outlet h3 | inch / mm | 1 / 1596 | 1 / 1598 |
| Heating coil return h4 | inch / mm | 1 / 706 | 5/4 / 708 |
| Heating coil supply h5 | inch / mm | 1 / 1446 | 5/4 / 1448 |
| Temperature sensor pocket h6 | mm | 891 | 893 |
| Electric heating element connection h8 | inch / mm | 6/4 / 751 | 6/4 / 753 |
| Temperature sensor pocket h9 | mm | 1451 | 1453 |
| Air vent connection h10 | inch / mm | 1/2 / 389 | 1/2 / 380 |
| Temperature measurement port h11 | inch / mm | 1/2 / 316 | 1/2 / 307 |
| Electric heating element connection h12 | inch / mm | 6/4 / 258 | 6/4 / 258 |
| Temperature measurement port h13 | inch / mm | 1/2 / 217 | 1/2 / 208 |
| Boiler water connection h14 | inch / mm | 1 / 141 | 1 / 132 |
| Boiler water connection h15 | inch / mm | 1 / 224 | 1 / 215 |
| Boiler water connection h16 | inch / mm | 1 / 309 | 1 / 300 |
| Boiler water connection h17 | inch / mm | 1 / 392 | 1 / 383 |
| Temperature sensor pocket h19 | mm | 1299 | 1301 |
Heat exchanger and tank parameters
| Technical data | Unit | THP-205/75 | THP-290/105 |
|---|---|---|---|
| Heating coil capacity | l | 15.2 | 24 |
| Heating coil surface area | m2 | 2.4 | 3.2 |
| Heat exchanger output (70/10/45°C) | kW | 56 | 74 |
| Continuous heat exchanger output | l/h | 1400 | 1800 |
| Heating coil operating pressure | MPa | 1 | 1 |
| Operating pressure of upper DHW tank / lower CH buffer | MPa | 0.6 / 0.3 | 0.6 / 0.3 |
| Height H | mm | 1677 | 1692 |
| Diameter with insulation D / without insulation d | mm | 677 / 550 | 737 / 601 |
| Total capacity of upper tank | l | 224 | 281 |
| Capacity of upper DHW tank / lower CH buffer, V | l | 211 / 80 | 251 / 93 |
| Surface area | m2 | 4.6 | 5.6 |
| Weight | kg | 111 | 132 |
| Tilting diagonal R | mm | 1802 | 1838 |
| Magnesium anode weight | kg | 0.9 | 1.1 |
| Length of main / additional magnesium anodes | mm | 400 / 400 | 500 / 400 |
| Energy efficiency class | - | A | A |
Are KHT THP-GP-PU heating towers suitable for use with heat pumps?
Yes.