Boiler for pellets Defro Alfa II 12 kW
Alfa II is designed for heating single-family houses, residential buildings and smaller public buildings. It is an automatic boiler, consisting of a boiler body and a fuel feeding system, which was placed in the casing. Casing consists of: combustion chamber, ashtray chamber, heat exchanger and flue gas outlet channel. Alfa II boiler It has a new intuitive APC 3 controller with a colour and touch screen. The stove can also work with a hot water installation with a heat exchanger.
Alfa II is designed for installation in an open heating system according to the PN-B-024 13:1991 standard. In case of installation in a closed heating system, a protection meeting the requirements of PN-EN 12828 and PN-EN 303-5 should be applied, while working pressure cannot exceed 2.5 bar.
It comes in two versions: STANDARD and PLUS, difference lies in the size of fuel tank (exact values are shown in table below):
Standard equipment:
- control APC CENTER,
- PID function,
- leveling feet,
- fuel lighter,
- central pellet burner with automatic cleaning function,
- hydraulic kit with thermostatic valve and circulation pump,
- exhaust fan,
- fuel feed system,
- fuel tank,
- hydraulics kit,
- ash container for cleaning system,
- automatic ash removal system,
- ash tray,
Optional equipment:
- GSM module,
- room regulator,
- thermal safety bleeding module with automatic filling of the 544 series,
- additional mixing valve controller,
The boilers meet the class 5 energy and emission requirements of PN EN 303-5: 2012 and Ecodesign requirements.
Manufacturer gives 5 years warranty for the tightness of heat exchanger, 2 years for other components and efficient operation of boiler.
Basic dimensions of Alfa II boiler
Basic components of Alfa II boiler
- steel body with thermal insulation;
- door cover;
- hearth doors;
- viewfinder;
- ash door;
- supply spigot;
- return spigot
- drain spigot;
- leveling feet;
- fuel tank;
- electronic regulator;
- flue gas sensor mounting connector;
- flue gas sensor connection;
- STB temperature limiter;
- exhaust outlet connection (flue);
- exhaust fan;
- cable gland;
- return sensor cover;
- cable gland
- inspection doors of electric drives, control system, main fuel level sensor switch, feeder temperature, vacuum;
- sensor socket cover;
- service cover;
- push back cover of the clean top cover and vent;
- retractable fuel tank cover;
- ash container;
- flame bumper;
- electric fuel lighter;
- pellet burner with grate cleaning function;
- fuel feeder;
- main switch;
- air intake / air intake for combustion (ATTENTION, patency must be ensured);
- service cover;
- ash tray;
- exchanger cover;
- ash removal system gearmotor;
- burner grate cleaning system;
- hydraulic kit;
- fuel level sensor;
Boiler name |
Defro Alfa II |
||||||
Specification / type of boilera | 12 | 17 | 22 | 26 | 30 | 40 | |
Nominal power | kW | 12 | 17 | 22 | 26 | 30 | 40 |
Power range | kW | 3,6-12 | 5,1-17 | 6,6-22 | 7,5-26 | 9,0-30 | 11,1-40 |
Boiler class according to PN-EN 303-5 |
- | exhaust emissions / efficiency - class 5 | |||||
ECODESIGN |
- | Yes | |||||
Energy efficiency class |
- | A+ | |||||
Water temperature on the flow |
[ºC] |
65/80 | |||||
Basic fuel |
- | sawdust granules - pellets Ø6 - 8mm | |||||
Heating surface |
m2 |
1,4 | 1,6 | 1,9 | 2,3 | 2,7 | 9,0 |
Area of heated rooms 1 |
m2 |
do 150 | do 215 | do 275 | do 325 | do 375 | do 500 |
Fuel tank capacity (standard / enlarged) 2 |
kg | ∼90/∼153 | ∼90/∼153 | ∼114/∼190 | ∼127/∼202 | ∼151/∼225 | ∼174/∼225 |
Optimal thermal efficiency |
% | ~91,0-93,2 | |||||
Max. permissible operating pressure |
bar | 1,5 | |||||
Exhaust draft required |
Pa | 17 | 20 | 20 | 23 | 22 | 31 |
Boiler weight4 |
kg | 357 | 373 | 400 | 452 | 488 | 536 |
Boiler water capacity |
l | 55 | 56 | 65 | 78 | 88 | 100 |
Chimney cross section |
cmxcm | 14x14 | 14x14 | 16x16 | 16x16 | 18x18 | 18x18 |
Chimney cross section |
Ø mm | 160 | 160 | 180 | 180 | 200 | 200 |
Minimum chimney height |
m | 5 | 5,5 | 6 | 6,5 | 7 | 7,5 |
Diameter of supply and return connections |
GW1’’ | ||||||
Diameter of the spigot drainage |
½’’ | ||||||
Power supply |
V/Hz | ∼230/50 | |||||
Maximum permissible ambient temperature |
ºC | 50 |
1 Maximum area of heated compartments estimated for unit heat demand q=80W/m² and standard height of compartments 2,5m.
2 Pellet bulk density 0,6 kg/dm³.
3 Fuel consumption for pellets with calorific value 17 000±300kJ/,
4 Weight of boiler depends on equipment. Weight of a boiler with an enlarged PLUS tank is about 20kg more.
5 Height of boiler can be additionally adjusted using included feet. The feet have an adjustment range of 38-50mm.
6 Width of ALFA II / ALFA II PLUS boiler is 388mm larger respectively.
7 Condition for installation in a closed system is the use of thermal protection, e.g. DBV-2.
Product specification
Hopper capacity | ~90/~153 dm³ |
Power output | 12 kW |
Weight | 357 kg |
Efficiency | 91.0-93.2 % |
Min. chimney diameter | 160 mm |
Boiler class (303-5:2012) | 5 |
Ecodesign | yes |
Water capacity | 55 L |
Boiler heating surface | 1.4 m² |
Required chimney draught | 17 Pa |
Min. chimney height | 5 m |
Outlet and inlet size | 1 inch |
Warranty | 60 months |
Opinions