Boiler Metal-Fach SEG PELLET 30 /P
Parameter | unit SI | Model of the boiler | |||
SEG PELLET 15 | SEG PELLET 20 | SEG PELLET 25 | SEG PELLET 30 | ||
Nominal thermal power | [kW] | 15 | 20 | 25 | 30 |
Boiler output range | [kW] | 4,5-15 | 6-20 | 7,5-25 | 9-30 |
A surface that can be heated | [m2] | 150 | 150-200 | 200-250 | 250-300 |
Heating surface | [m2] | 2,10 | 2,54 | 2,85 | 3,11 |
Water capacity | [L] | 60 | 68 | 73 | 95 |
Maximum working pressure | [bar] | 3 | |||
Maximum working temperature | [°C] | 95 | |||
Test pressure | [bar] | 4,5 | |||
ECODESIGN | [-] | + | |||
5 th Class acc. PN EN 303-5: 2012 standards | [-] | 5 | |||
Boiler efficiency | [%] | ≤92 | |||
Capacity of the fuel tank | [L] | 260 | |||
Capacity of the fuel tank | [kg] | 155 | |||
Fuel | [-] | pellet Φ6-8 | |||
Electrical connection | [-] | ~230V; 50 Hz | |||
Electric power consumption at boiler operation with nominal power | [W] | 80 | |||
Electric power consumption when lighting up the boiler | [W] | 380 | |||
Setting range of the temperature controller | [°C] | 60-85 (by 1°C) | |||
Chimney draft required | [Pa] | 20 | 25 | 25 | 30 |
Calculation of flow resistance ΔT = 10K | mbar | 5,47 | 9,74 | 12,33 | 15,80 |
Calculation of flow resistance ΔT. = 20K | mbar | 1,36 | 2,43 | 3,80 | 4,30 |
Boiler weight | [kg] | 448 | 510 | 535 | 551 |
DIMENSIONS
TYPE | SEG PELLET – 15 | SEG PELLET – 20 | SEG PELLET – 25 | SEG PELLET – 30 |
A | 1160 | 1160 | 1160 | 1210 |
B | 535 | 535 | 535 | 585 |
C | 1160 | 1355 | 1415 | 1415 |
C1 | 1425 | |||
D | 705 | 745 | 795 | 795 |
E | 910 | 1105 | 1160 | 1160 |
F | 350 | 360 | 410 | 410 |
G | 1,5” | |||
H | 3/4” | |||
I | 180 | |||
J | 1,5” | |||
K | 215 | 250 | ||
L | 215 | 210 | 205 | 205 |
M | 615 | |||
N | 715 | |||
O | 125 | |||
P | 870 | 905 | 955 | 955 |
Product specification
Fuels | Pellet |
Hopper capacity | 260 dm³ |
Power output | 30 kW |
Weight | 551 kg |
Exhaust gas pipe diameter | 180 mm |
Efficiency | 92 % |
Boiler class (303-5:2012) | 5 |
Ecodesign | yes |
Size of heated surface | 250 - 300 m² |
Water capacity | 95 L |
Boiler heating surface | 3.11 m² |
thickness of steel | 6 mm |
Height | 1415 mm |
Height | 1425 mm |
Width | 1210 mm |
Width without hopper | 585 mm |
Exhaust pipe distance measured from the floor to its axis. | 1160 mm |
Depth with exhaust pipe | 955 mm |
Max. water temperature | 95 °C |
Max working pressure | 3 bar |
Required chimney draught | 30 Pa |
Outlet and inlet size | 6/4” inch |
Power supply | 230V / 50Hz |
Warranty | 60 months |
Opinions
If you have experience with this product
add your opinion !
ℹ️ Viewed reviews are moderated. We do not verify that they come from customers who have purchased the product.