Induction - elektric boiler PEREKO π - PI - 21 kW on electricity
Π (PI) is designed for low-temperature water central heating systems, where temperature in system does not exceed 90°C.It can be installed in central heating installations made of steel, copper, polyethylene, polypropylene, CPVC, etc. pipes on which heaters of all types are mounted, as well as it cooperates with all types of heaters and air curtains.
Boiler Π (PI) is an inductive central heating boiler based on an electromagnetic device. The heat is created by an electromagnetic field directly in heating chamber which is located on the transformer columns. This design allows to reduce loss of electromagnetic field to a minimum. Exchanger chamber is made of high quality acid resistant steel. Expected boiler life is 50 years. Main element of boiler Π it is a three-phase dry transformer with a compact secondary winding. Secondary winding forms a heating chamber. All heat generated in chamber is transferred entirely to heating medium (water) which flows through chamber.)
WARRANTY: For induction boilers of &pi series; at the date of purchase, a standard 24-month warranty is given for smooth running of boiler as well as a 24-month warranty on components such as controller or sensors (etc.). However, it is possible to extend warranty even for period 20 years by registering boiler on manufacturer's website and receiving a written 20 year warranty for boiler.)
Dimensions PEREKO PI boiler
Parameter | Unit | Model | ||||
3,2 | 10 | 21 | ||||
Dimensions | L | [mm] | 520 | 587 | ||
S | [mm] | 356 | 405 | |||
H | [mm] | 666 | 535 | |||
Nominal power | [kW] | 3,2 | 10 | 21 | ||
Approximate heating surface | [m²] | 40 – 80 | 60 – 180 | 160 – 350 | ||
Frequency | [Hz] | 50 | ||||
Efficiency | [%] | 98 | ||||
Maximum current consumption | [A] | 16 | 28 | |||
Rated current of overcurrent circuit breaker | [A] | 25 | 20 | 40 | ||
Minimum cross-section of supply cable | [mm2] | 3 x 1,5 | 5 × 2,5 | 5 × 6 | ||
Maximum cross-section of supply cable | [mm2] | 3 x 2,5 | 5 x 16 | |||
Pressure permitted | [MPa] | 0,3 | ||||
Minimum pressure | [MPa] | 0,05 | ||||
Adjustable outlet temperature | [°C] | ≤ 85 | ||||
Outlet temperature permissible | [°C] | 90 | ||||
Working time | [h] | unlimited | ||||
Power supply | [V] | 1 x 230 V | 3L ~ 400 V | |||
Weight | [kg] | 85 | 128 | 178 | ||
Degree of protection | — | IP 21 | ||||
Boiler connections | [cal] | 3/4 |
PEREKO Π (PI) simplified scheme of boiler components.
- Control panel
- Boiler temperature sensor
- STB
- Flow sensor
- Relay ssr
- Fan Relay Radiator
- Exchanger
- Executive module
- Overcurrent fuse
- Power cable connection
- Original winding
- Circulation pump connection sockets: HUW, ZB, CO
- Sockets for temperature sensors: HUW, ZB, room regulator
- Power cable inlet
Boiler is an electromagnetic device that converts three-phase electrical energy (current) into heat by means of an electromagnetic field. In this process water is subjected to electromagnetic treatment.
Energy classification of buildings according to the Association for Sustainable Development of Poland
Energy class | Type of building | EU indicator [kWh/m²/year] | Method of heating | Source | |
Media | Efficiency [%] | ||||
A++ | Zero-energy | ≤ 10 | Electricity | 100 | Photovoltaics, wind energy, electricity distributor |
A+ | Passive | 10 – 15 | |||
A | Low-energy | 15 – 45 | |||
B | Energy-saving | 45 – 80 | Electricity, natural gas | 98 – 100 | Photovoltaics, wind energy, electricity distributor, natural gas distributor |
C | Średnio energooszczędny | 80 – 100 | |||
D | Legal minimum (meeting current legal requirements) | 100 – 150 | Electricity, natural gas, coal, wood | 68 – 100 | |
E | Energy-intensive | 150 – 250 | Natural gas, coal, wood | 68 – 98 | |
F | Highly energy-intensive | ≥ 250 | Coal, wood | 68 | — |
Once the Energy Demand Coefficient of a building has been determined [kW/m2/year] remember the value and enter it in induction boiler heating cost calculator PI
Induction boiler heating cost calculator π
To ensure the most economical operation of induction boiler, it is best to combine it with a buffer, accumulation tank, together with an electrical connection operating at a tariff (G12), i.e. night-time. If this is not required by other heat sources, a buffer without coils is recommended. By buffer, accumulation tank, we mean an insulated tank, which has the task of accumulating the heat energy produced by the boiler and putting this energy into the installation when the boiler is not working. During the operation of the boiler the circulation pump constantly mixes water in buffer, drawing cold water from its lower part and feeding hot water from upper part. For an average house it is enough to install a storage tank, buffer, with a capacity of about 700 - 800 liters of water. Dimensions of such a buffers are so small that they can be installed in any boiler room.
Product specification
Power output | 21 kW |
Weight | 130 kg |
Efficiency | 98 % |
Size of heated surface | 160 - 350 m² |
Height | 535 mm |
Width | 587 mm |
Depth | 405 mm |
Max. water temperature | 90 °C |
Max working pressure | 3 bar |
Outlet and inlet size | 3/4 inch |
Power supply | 400V / 50Hz |
Warranty | 24 months |
Warranty | 20 years |
Opinions