Induction - elektric boiler PEREKO π - PI - 21 kW on electricity

Induction - elektric boiler PEREKO π - PI - 21 kW on electricity

EAN: 5908218391086| NN: 10668

32190.00 PLN

28490.00

PLN Incl. VAT

Cost: Individual calculation
(After placing your order we will send you a non-binding offer containing delivery costs.)
Bank transfer
DotPay - credit card

Π (PI) is designed for low-temperature water central heating systems, where temperature in system does not exceed 90°C.It can be installed in central heating installations made of steel, copper, polyethylene, polypropylene, CPVC, etc. pipes on which heaters of all types are mounted, as well as it cooperates with all types of heaters and air curtains.

Boiler Π (PI) is an inductive central heating boiler based on an electromagnetic device. The heat is created by an electromagnetic field directly in heating chamber which is located on the transformer columns. This design allows to reduce loss of electromagnetic field to a minimum. Exchanger chamber is made of high quality acid resistant steel. Expected boiler life is 50 years. Main element of boiler Π it is a three-phase dry transformer with a compact secondary winding. Secondary winding forms a heating chamber. All heat generated in chamber is transferred entirely to heating medium (water) which flows through chamber.)

WARRANTY: For induction boilers of &pi series; at the date of purchase, a standard 24-month warranty is given for smooth running of boiler as well as a 24-month warranty on components such as controller or sensors (etc.). However, it is possible to extend warranty even for period 20 years by registering boiler on manufacturer's website and receiving a written 20 year warranty for boiler.)

Dimensions PEREKO PI boiler

Dimensions PEREKO PI
Parameter Unit Model
3,2 10 21
Dimensions L [mm] 520 587
S [mm] 356 405
H [mm] 666 535
Nominal power [kW] 3,2 10 21
Approximate heating surface [m²] 40 – 80 60 – 180 160 – 350
Frequency [Hz] 50
Efficiency [%] 98
Maximum current consumption [A] 16 28
Rated current of overcurrent circuit breaker [A] 25 20 40
Minimum cross-section of supply cable [mm2] 3 x 1,5 5 × 2,5 5 × 6
Maximum cross-section of supply cable [mm2] 3 x 2,5 5 x 16
Pressure permitted [MPa] 0,3
Minimum pressure [MPa] 0,05
Adjustable outlet temperature [°C] ≤ 85
Outlet temperature permissible [°C] 90
Working time [h] unlimited
Power supply [V] 1 x 230 V 3L ~ 400 V
Weight [kg] 85 128 178
Degree of protection IP 21
Boiler connections [cal] 3/4

PEREKO Π (PI) simplified scheme of boiler components.

PEREKO PI
  1. Control panel
  2. Boiler temperature sensor
  3. STB
  4. Flow sensor
  5. Relay ssr
  6. Fan Relay Radiator
  7. Exchanger
  8. Executive module
  9. Overcurrent fuse
  10. Power cable connection
  11. Original winding
  12. Circulation pump connection sockets: HUW, ZB, CO
  13. Sockets for temperature sensors: HUW, ZB, room regulator
  14. Power cable inlet

Boiler is an electromagnetic device that converts three-phase electrical energy (current) into heat by means of an electromagnetic field. In this process water is subjected to electromagnetic treatment.

 

Energy classification of buildings according to the Association for Sustainable Development of Poland

Energy class Type of building EU indicator [kWh/m²/year] Method of heating Source
Media Efficiency [%]
A++ Zero-energy ≤ 10 Electricity 100 Photovoltaics, wind energy, electricity distributor
A+ Passive 10 – 15
A Low-energy 15 – 45
B Energy-saving 45 – 80 Electricity, natural gas 98 – 100 Photovoltaics, wind energy, electricity distributor, natural gas distributor
C Średnio energooszczędny 80 – 100
D Legal minimum (meeting current legal requirements) 100 – 150 Electricity, natural gas, coal, wood 68 – 100
E Energy-intensive 150 – 250 Natural gas, coal, wood 68 – 98
F Highly energy-intensive ≥ 250 Coal, wood 68

Once the Energy Demand Coefficient of a building has been determined [kW/m2/year] remember the value and enter it in induction boiler heating cost calculator PI

Induction boiler heating cost calculator π

To ensure the most economical operation of induction boiler, it is best to combine it with a buffer, accumulation tank, together with an electrical connection operating at a tariff (G12), i.e. night-time. If this is not required by other heat sources, a buffer without coils is recommended. By buffer, accumulation tank, we mean an insulated tank, which has the task of accumulating the heat energy produced by the boiler and putting this energy into the installation when the boiler is not working. During the operation of the boiler the circulation pump constantly mixes water in buffer, drawing cold water from its lower part and feeding hot water from upper part. For an average house it is enough to install a storage tank, buffer, with a capacity of about 700 - 800 liters of water. Dimensions of such a buffers are so small that they can be installed in any boiler room.

Product specification

Power output 21 kW
Weight 130 kg
Efficiency 98 %
Size of heated surface 160 - 350 m²
Height 535 mm
Width 587 mm
Depth 405 mm
Max. water temperature 90 °C
Max working pressure 3 bar
Outlet and inlet size 3/4 inch
Power supply 400V / 50Hz
Warranty 24 months
Warranty 20 years

Opinions

If you have experience with this product add your opinion !

ℹ️ Viewed reviews are moderated. We do not verify that they come from customers who have purchased the product.

Your mark
On this website we are using cookies files. If you want, you can turn off cookies in your browser settings. OK, close ad or find out more.