Accumulation tank with 2 black steel coils GALMET SG(B) 400 insulated
Catalog number: 72-400000|
EAN: 5901224719462|
NN: 34889
Advantages of using an accumulation tank:
- Longer life of boiler, chimney and other parts of heating system thanks to use of a buffer tank in central heating system
- Less risk of boiling water in boiler
- Improved use of thermal energy by about 40%
- Very high reduction of tar production in boiler
- High combustion efficiency in boiler
- Simplified boiler operation because boiler operates at optimum output
- Less labour-intensive boiler cleaning and less ash production
Parameter /Model |
Units |
SG(B) 400 |
SG(B) 500 |
SG(B) 800 |
SG(B) 1000 | SG(B) 1500 | SG(B) 2000 |
Capacity | l | 361 | 433 | 688 | 835 | 1421 | 1960 |
ErP | polyurethane foam | C | C | - | - | - | - |
Neodul |
- | - | C | C | C | C | |
Working Pressure tank |
MPa | 0,3 | 0,3 | 0,3 | 0,3 | 0,3 | 0,3 |
Max. working temperature tank |
oC |
95 | 95 | 95 | 95 | 95 | 95 |
Internal diameter, d |
Ø mm |
600 | 600 | 790 | 790 | 900 | 1100 |
External diameter, D |
Ø mm |
700 |
700 | 950 | 950 | 1100 | 1300 |
Height L |
mm | 1685 | 1925 | 1730 | 2050 | 2700 | 2500 |
height when tilted |
mm | - | - | 1995 | 2270 | 2920 | 2820 |
Coil working pressure |
MPa |
0,6 |
0,6 | 0,6 | 0,6 | 0,6 | 0,6 |
Surface of the solar coil |
m2 |
1,8 |
2,5 | 3 | 3,5 | 4 | 4,5 |
Capacity of the solar coil |
l |
12,6 | 17,5 | 20,9 | 24,4 | 28 | 31,5 |
Surface of the upper coil |
m2 |
1,4 | 1,4 | 1,8 | 2,1 | 2,5 | 2,7 |
Capacity of the upper coil |
l |
9,8 | 9,8 | 12,6 | 14,7 | 17,5 | 18,9 |
Weight |
kg | 145 | 170 | 205 | 240 | 320 | 370 |
Insulation |
[-] | polyurethane foam | polyurethane foam | Neodul | Neodul | Neodul | Neodul |
Dimensions /Model |
Units |
SG(B) 400 | SG(B) 500 |
SG(B) 800 |
SG(B) 1000 | SG(B) 1500 | SG(B) 2000 |
h1 | mm | 250 | 250 | 250 | 250 | 330 | 385 |
h2 | mm | 445 | 485 | 435 | 500 | 705 | 660 |
h3 | mm | 565 | 645 | 570 | 570 | 915 | 800 |
h4 | mm | 635 | 715 | 620 | 740 | 1015 | 930 |
h5 | mm | 825 | 945 | 820 | 980 | 1325 | 1205 |
h6 | mm | 850 | 1050 | 900 | 1100 | 1230 | 1285 |
h7 | mm | 1010 | 1150 | 1000 | 1200 | 1565 | 1415 |
h8 | mm | 1015 | 1180 | 1020 | 1240 | 1640 | 1480 |
h9 | mm | 1150 | 1300 | 1150 | 1350 | 1715 | 1565 |
h10 | mm | 1210 | 1410 | 1215 | 1485 | 1950 | 1755 |
h11 | mm | 1410 | 1550 | 1320 | 1640 | 2110 | 1885 |
h12 | mm | 1410 | 1640 | 1410 | 1730 | 2260 | 2025 |
h13 | mm | 1420 | 1650 | 1420 | 1740 | 2260 | 2035 |
Product specification
Boiler water capacity | 361 l |
Amount of coils | 2 item |
Weight (without isolation) | 145 kg |
Maximum boiler water temperature | 100 °C |
Maximum pressure for boiler water tank | 0.3 MPa |
Coil size (bottom) | 1.8 m² |
Coil size (top) | 1.4 m² |
Height | 1685 mm |
Diameter (without isolation) | 600 mm |
Diameter (with isolation) | 700 mm |
Isolation | 70 mm |
External Enclosure | skay |
Boiler connections | 6/4 inch |
Solar circuit (inlet/outlet) | 1 inch |
Central heating circuit (inlet/outlet) | 1 inch |
Release | 1 inch |