Manual fired boiler for coal PROSAT UNI 13 kW
Regular price:
product unavailable
add to wish list
Description
PROSAT UNI
The PROSAT boiler of the UNI type is a boiler designed to heat water in a central heating system as well as to heat domestic hot water. It is a boiler in which fuel is supplied to the combustion chamber manually through the hopper door. It uses bottom combustion technology for hard coal, ensuring economical and clean fuel combustion.
To achieve optimal combustion conditions, the regulation of the amount of incoming air is performed using a throttle on the lower doors, whose adjustment is manual or with the help of a draft gauge, throttles on the middle doors, as well as through secondary air throttles located on the side of the boiler. The boiler must be operated with an accumulation tank to meet the requirements of the PN-EN 303-5:2012 standard.
Advantages
- Heat exchanger made from certified boiler sheet metal
- Primary fuel: hard coal
- High combustion and heat exchange efficiency: above 89%
- Compact boiler design
- Combustion chamber with ceramic catalysts
- Adapted for thermostatic draft regulator installation
- Adjustable secondary air nozzle
Technical Data
| Technical Data | [Unit] | UNI 10 | UNI 13 | UNI 18 | UNI 24 |
| Nominal heat output | [kW] | 10 | 13 | 18 | 24 |
| Fuel burn time | [h] | 4.5 | |||
| Boiler heating surface | [m2] | 1.3 | 1.7 | 2.4 | 3.2 |
| Boiler water capacity | [l] | 62 | 72 | 88 | 100 |
| Approximate heated area size | [m2] | up to 120 | up to 160 | up to 220 | up to 280 |
| Boiler class according to PN-EN 303-5:2012 | [-] | ecodesign | |||
| Efficiency | [%] | 89 | |||
| Fuel chamber capacity | [dm3] | 24 | 28 | 36 | 48 |
| Max. supply temperature | [°C] | 85 | |||
| Min. supply temperature | [°C] | 55 | |||
| Average flue gas temperature | [°C] | 143 | 120 | 145 | |
| Max water temperature supplying buffer tank | [°C] | 85 | |||
| Max. allowable working pressure | [Mpa] | 0.2 | |||
| Test pressure | [Mpa] | 0.35 | |||
| Required flue gas draft | [mbar] | 0.2 | 0.25 | ||
| Minimum buffer tank capacity | [L] | 600 | 800 | 1200 | 1600 |
| Chimney cross-section min. | [cm2] | 250 | 400 | ||
| Minimum chimney height | [m] | 6 | |||
| Flue collar diameter | [mm] | 150 | 160 | ||
| Boiler mass | [kg] | 243 | 254 | 315 | 336 |
| Supply and return connector diameter | [inch] | 1 | 1 1/2 | ||
| Draft gauge connector diameter | [inch] | 3/4 | |||
| Noise emission | [dB] | < 30 | |||
| Height | [mm] | 1190 | 1230 | 1280 | |
| Width | [mm] | 455 | 595 | ||
| Depth | [mm] | 595 | 650 | 700 | |
Technical data
| Power output | 13 kW |
| Exhaust gas pipe diameter | 150 mm |
| Efficiency | 89 % |
| Ecodesign | + |
| Height | 1230 mm |
| Width | 455 mm |
| Depth | 650 mm |
| Minimum chimney section | 250 cm² |
| Outlet and inlet size | 1 G |
| Producer's recommended minimum volume of accumulation tanks | 800 L |

All reviews (positive and negative) are displayed. We don't verify that they come from customers who have purchased the product.