Manual fired boiler for coal PROSAT UNI 10 kW
Regular price:
product unavailable
add to wish list
Description
PROSAT UNI
The PROSAT UNI type boiler is a boiler designed for heating water in a central heating system as well as for heating hot utility water. It is a boiler in which fuel is supplied to the combustion chamber manually through loading doors. It uses bottom combustion technology for hard coal ensuring economical and clean fuel combustion.
To achieve optimal combustion conditions, the regulation of the amount of incoming air is performed using a throttle of the lower doors, which can be adjusted manually or with a draft gauge, a throttle of the middle doors, as well as through secondary air throttles located on the side of the boiler. The boiler must be operated with an accumulation tank to meet the requirements of the PN-EN 303-5:2012 standard.
Advantages
- Heat exchanger made of certified boiler sheet
- Primary fuel: hard coal
- High combustion and heat exchange efficiency: above 89%
- Compact boiler design
- Combustion chamber with ceramic catalysts
- Adapted for installation of thermostatic draft regulator
- Adjustable secondary air nozzle
Technical Data
| Technical Data | [Unit] | UNI 10 | UNI 13 | UNI 18 | UNI 24 |
| Nominal heat output | [kW] | 10 | 13 | 18 | 24 |
| Burn time | [h] | 4.5 | |||
| Boiler heating surface | [m2] | 1.3 | 1.7 | 2.4 | 3.2 |
| Boiler water capacity | [l] | 62 | 72 | 88 | 100 |
| Approximate heated surface area | [m2] | up to 120 | up to 160 | up to 220 | up to 280 |
| Boiler class according to PN-EN 303-5:2012 | [-] | ecodesign | |||
| Efficiency | [%] | 89 | |||
| Fuel chamber capacity | [dm3] | 24 | 28 | 36 | 48 |
| Max. supply temperature | [°C] | 85 | |||
| Min. supply temperature | [°C] | 55 | |||
| Average flue gas temperature | [°C] | 143 | 120 | 145 | |
| Max water temperature feeding buffer tank | [°C] | 85 | |||
| Max. permissible working pressure | [Mpa] | 0.2 | |||
| Test pressure | [Mpa] | 0.35 | |||
| Required flue gas draft | [mbar] | 0.2 | 0.25 | ||
| Minimum buffer tank capacity | [L] | 600 | 800 | 1200 | 1600 |
| Min. chimney cross-section | [cm2] | 250 | 400 | ||
| Minimum chimney height | [m] | 6 | |||
| Flue collar diameter | [mm] | 150 | 160 | ||
| Boiler mass | [kg] | 243 | 254 | 315 | 336 |
| Diameter of supply and return tappings | [in] | 1 | 1 1/2 | ||
| Diameter of draft gauge tapping | [in] | 3/4 | |||
| Noise emission | [dB] | < 30 | |||
| Height | [mm] | 1190 | 1230 | 1280 | |
| Width | [mm] | 455 | 595 | ||
| Depth | [mm] | 595 | 650 | 700 | |
Technical data
| Power output | 10 kW |
| Exhaust gas pipe diameter | 150 mm |
| Efficiency | 89% |
| Ecodesign | + |
| Height | 1190 mm |
| Width | 455 mm |
| Depth | 595 mm |
| Minimum chimney section | 250 cm² |
| Outlet and inlet size | 1 G |
| Producer's recommended minimum volume of accumulation tanks | 600 L |

All reviews (positive and negative) are displayed. We don't verify that they come from customers who have purchased the product.