Air as a renewable energy source

Heat pump Basic is an ideal source for heating domestic hot water for single-family homes. A heat pump with a tank secures domestic hot water at a temperature of up to 55°C in a quantity of 270 liters. The heat pump installation does not require expensive boreholes as in the case of ground source heat pumps. The Basic pump is designed for installation inside the building and requires only: hydraulic and electrical connections as well as air duct connections. Special controller functions ensure that the heat pump is used safely and conveniently. The PARTY function is an ideal solution when there are temporarily more people in the house and rapid heating of domestic hot water is required. To care for the health of users, the pump has an Antilegionella function which prevents bacterial growth. The pump has a function to optimize pump operation called ECO. Frost protection is a safeguard for the pump itself. Energy efficiency class A confirms low power consumption. The Basic heat pump is equipped with a constant monitoring option as standard. Basic pump parameters are displayed on the controller's touch LCD screen. This enables control of the circulation pump operation. Proper programming of times and periods of hot water demand reduces the waiting time for hot water at the tap. It allows maintaining water at a set temperature. Each Basic pump controller contains a database of optimal configurations for heating domestic hot water. It provides the ability to program an hourly schedule of pump operation, e.g. to take advantage of the benefits of night rate tariff. Controlling pump functions and changing parameters is enabled by a dedicated room controller. The Basic pump allows partial cooling or dehumidifying of the room in which it operates. To ensure convenient and quick installation, each Basic heat pump is offered with the necessary ventilation components.

Parameter Unit

BASIC 270 with 2 coils

09-355201

COP   3.79
Tank capacity l 270
Number of coils / air ºC 2
Pump application range ºC +7÷+35
Hot water temperature ºC 55
Refrigerant   R134a
Heat pump heating power kW 2
Electric heater power kW 2
Total heating power (heat pump + heater) kW 4
Spiral coil surface area m2 1.0 / 0.7
Weight kg 185
Supply voltage IP42
Dimensions (height x width x depth) V 230
Connection fittings " 1"
Circulation connection fitting " 3/4"
Condensate connection mm 12
Rated power consumption W 413
Maximum tank working pressure MPa 1
Maximum heat exchanger working pressure MPa 1.6
Acoustic power level dB 56
Air duct diameter mm 160
Maximum air duct length mm 160
Dimensions height x diameter mm 1730 x 670
Electrical protection   C16
Air flow m3/h 313
Compressor   Embraco/Danfoss

According to PN-EN 255-3; A - air temperature; W - water heating temperature range

 

An air-to-water heat pump equipped with two coils enables heating from practically three heat sources. In the winter period, water heating can be carried out via a central heating boiler connected to one coil supported by a solar installation connected to the second coil. In the summer period, water can be heated using solar alone or a heat pump. This way we cover the demand for domestic hot water in every season with maximum energy and cost savings.

Heat pump air duct connection

Air supply ducts



The length of discharge and intake ducts cannot exceed 5m. Installing a 90° elbow is counted as shortening the duct by 2m. If it is necessary to exceed the maximum duct length, it is recommended to use appropriate fans to support air flow.

 

Heat pump installation inside the building

Recommended distances



The location of the heat pump in the room should ensure service access to at least one side of the device. The minimum distance from the wall is 40 cm. The minimum installation area is 2 x 2 m and the room height is at least 2 m.

 

Heat pump power supply from boiler room and air discharge outside

from outside to inside


 

IMPORTANT! Need to ensure proper ventilation of the room in which the heat pump is located

 

Heat pump location inside boiler room

from inside to inside


 

IMPORTANT! A minimum distance of 1.5 m should be maintained between the intake and outlet ducts

 

Heat pump air supply and discharge outside

from outside to outside

Heat pump power supply from outside and air discharge to another room

from outside to inside
 

TECH ST 53.2 Controller

Modern touch controller for Basic heat pump - ST-53.2 with functions: ECO, ANTILEGIONELLA, PARTY.
ST-53.1
 

Technical data

Power output 4 kW
Energy efficiency class A
Weight 185 kg
Capacity 270 l
COP 3.79
Loudness 56 dB
Amount of coils 2 szt.
Max working pressure 10 bar
Connector 1 cal
Power supply 230V / 50Hz
Height 1730 mm

Shipping costs The price does not include any possible payment costs

Shipping country:

Related products

Product reviews (0)

All reviews (positive and negative) are displayed. We don't verify that they come from customers who have purchased the product.

up
Shop is in view mode
View full version of the site
Sklep internetowy Shoper Premium