Deflector for PER-EKO KSR 14,17,25 kW boiler
Diameter: 180 mm
The deflector is installed in a boiler with an auger feeder. It is suspended above the furnace.
The deflector is an operating component of the boiler and, like the grate in conventional boilers, is subject to wear and therefore needs to be replaced after some time. The service life of the deflector is significantly shortened when the blast from the fan is too large and too intense. If the deflector is damaged after a short period of operation, this is not a boiler defect but an obvious consequence of blowing excessive amounts of air into the boiler. Aggressive heat from the retort has led to deflector damage. In such a situation, the boiler does not operate as a heating device, but as a blacksmith's furnace where steel is melted and the deflector can burn through.