Boiler for pellets Defro SMART EKOPELL 16

Kocioł na pellety Defro SMART EKOPELL 16
  • discount
Availability: temporarily unavailable
Delivery: The price does not include any possible payment costs check the delivery methods
Price: DKK33,839.29

Regular price: DKK39,778.57

33839.29
The lowest price during 30 days prior to the reduction: DKK32,946.43

The promotion runs until 24 July 2026

quantity pcs

product unavailable

add to wish list
* - Field mandatory

Description

The automatic pellet boiler Defro Smart Ekopell has a reinforced structure and a built-in cooling coil that enables safe operation in a closed system. The pellet burner is made of the best materials, has an automatic cleaning function and two igniters as standard (Twin Spark System). The boiler is equipped with an innovative controller with a color touch screen that controls 6 pumps. It also has high efficiency reaching 90%. The boiler tank has a fuel reserve sensor; when the fuel level is minimal, the boiler operation is stopped, and after refueling, ignition occurs automatically.

Standard Equipment:

  • APC 3 ADAPTIVE CONTROL controller,
  • ADAPTIVE CONTROL control,
  • Internet module,
  • leveling feet,
  • igniter,
  • extraction fan,
  • mechanical cleaning system for the heat exchanger,
  • boiler adapted for installation in a closed system (option for an additional fee),
  • pellet burner with automatic cleaning function,
  • blower fan,
  • flue gas swirlers (economizers),
  • ash drawer,
  • chimney extension with damper,
  • fuel tank,
  • fuel supply system with burner,
  • BVTS thermostatic valve,
  • cooling coil.

Optional Equipment (additional fee):

  • GSM module,
  • WIFI internet module,
  • DEFRO SPK Lux room regulator,
  • DEFRO MZ module,
  • SPK Lux wireless regulator,
  • wireless RS communication kit
  • DK LOGIC 100 regulator.

CONTROLLER - APC 3 ADAPTIVE CONTROL

APC 3 Controller

FUNCTIONS PERFORMED BY THE CONTROLLER:

  • innovative ADAPTIVE Control with the use of a turbine flow meter ensuring optimal selection of fan and feeder operation parameters;
  • boiler ignition and shutdown is automatic;
  • igniter control;
  • control of blower fan, extraction fan and feeder;
  • control of CO, DHW, additional pumps and two valve pumps;
  • control of additional device;
  • control of two mixing valves;
  • fuel level sensor and fuel consumption measurement – protects against complete depletion of the fuel supply system;
  • option to set daily boiler operation;
  • weekly boiler, DHW and valve temperature control;
  • weather control;
  • internet module (included in the equipment) enables changing boiler operation and control parameters (access to user and service menus, possibility of remote boiler ignition and shutdown);
  • cooperation with a room regulator with traditional (two-state) communication or equipped with RS communication – SPK LUX;
  • possibility of connecting the DEFRO GSM module (control via mobile phone);
  • possibility of connecting two additional valve control modules (e.g.: DEFRO MZ) – enables control of two additional valves.
Specification / boiler type Unit 12 16 20 24 28 38
Nominal power [kW] 12 16 20 24 28 38
Power range [kW] 3.6 - 12 4.8 - 16 6.0 - 20 7.2 - 24 8.4 - 28 11.4 - 38
Boiler class according to PN-EN 303-5 [-] 5
Ecodesign   YES YES YES YES YES YES
Heating surface [m2] 1.6 1.8 2.2 2.6 3.2 3.6
Heat transmitted to surroundings [kW] 0.29 0.38 0.48 0.58 0.67 0.91
Area of heated rooms [m2] up to 120 up to 160 up to 200 up to 240 up to 280 up to 380
Primary fuel [-] granules from sawdust - pellet Ø6 - 8mm
Fuel class [-] biogenic fuel - C1
Fuel tank capacity [kg] 195
Fuel consumption [kg/h] 2.7 3.6 4.5 5.4 6.3 8.5
Optimal thermal efficiency [%] 88.3-90.1
Max. allowable working pressure [bar] 2.5
Required flue gas draft [mbar] 0.20 0.22 0.24 0.26 0.28 0.29
Flue gas temperature
at nominal power
at minimum power

[ºC]
[ºC]

100 - 119
63 - 64
Flue gas mass flow
at nominal power
at minimum power

[g/s]
[g/s]

8.0
3.8

10.4
4.6

12.9
5.3

15.3
6.1

17.7
6.9

23.8
8.8
Water temperature at outlet min./max [ºC] 65 / 80
Water temperature at return min. [ºC] 55
Temperature control range [ºC] 45 - 80
Temperature control range [kg] n.a.
Boiler water capacity [l] 51 57 64 73 86 98
Chimney dimensions [cm x cm]
[Ømm]
14 x 14
160
14 x 14
160
14 x 14
160
15 x 15
170
16 x 16
180
18 x 18
200
Minimum chimney height [m] 6 6.5 7.0 7.5 8.0 9.0
Power supply [V/Hz] 230V/50Hz
Power consumption (operation/startup) [W] 112 / 412 112 / 412 112 / 412 112 / 412 187 / 487 187 / 487
Width [mm]

Technical data

Boiler class (303-5:2012) 5
Power output 16 kW
Exhaust gas pipe diameter 127 mm
Weight 396 kg
Efficiency 88.3 - 90.1 %
Size of heated surface 160 m²
Ecodesign +
Height 1348 mm
Width 1232 mm
Depth 1393 mm
Outlet and inlet size 6/4 G
Warranty 60 mies.
Power supply 230V / 50Hz
Min. incoming water temperature 55 °C
Min. chimney height 6.5 m
Silo volume 195 dm³
Max working pressure 2.5 bar
Max. water temperature 80 °C
Clean Air Program tak

Shipping costs The price does not include any possible payment costs

Shipping country:

Product reviews (0)

All reviews (positive and negative) are displayed. We don't verify that they come from customers who have purchased the product.

Shop is in view mode
View full version of the site