Boiler for coal 5-25mm PROSAT WE - 5 class -20 kW with feeder on right side

Availability: 1 pc
Product code: 00888
Delivery: The price does not include any possible payment costs check the delivery methods
Price: DKK21,767.86

Regular price:

21767.86
The lowest price during 30 days prior to the reduction:
quantity pcs

product unavailable

add to wish list
* - Field mandatory

Description

Boiler Class 5 PROSAT WE 20 kW - an ecological boiler meeting class 5 standards in compliance with PN-EN 303/5 2012, with an automatic fuel dosing system - ecoal. The boiler is adapted to work in open central heating systems. A microprocessor temperature controller manages the entire combustion process as well as the operation of central heating and domestic hot water pumps. Boiler operation is limited to refueling in the tank, removing ash from the ash pan, and periodic cleaning of the convection heat exchanger channels from soot.

Most important information:

  • high thermal efficiency 90%
  • class 5 certificate
  • 5 years warranty
  • boiler heat exchanger made of 6 mm thick sheet metal
  • simple boiler operation and cleaning
  • large cleaning openings
  • fully automatic boiler operation
  • controller: Tech ST37 RS
  • possibility of expanding controller functions (paid options)
  • boiler protections (screw auger sensor, thermal cut-off, feeder pin)

Functions performed by the ST-480 controller:

  • control of fan and screw auger or piston feeder
  • CH pump control
  • DHW pump control
  • floor pump control
  • circulation pump control
  • mixing valve actuator control
  • possibility of connecting a room regulator with RS or traditional communication
  • possibility of connecting the ST-65 GSM module
  • possibility of connecting the ST-505 ETHERNET module
  • possibility of controlling two valves using additional ST-61 v4 or ST-431n modules

ST-480 controller equipment:

  • large graphic display facilitating controller operation
  • CH temperature sensor
  • DHW and floor temperature sensor
  • valve and return temperature sensor
  • external temperature sensor (wireless)
  • feeder temperature sensor (protection)
  • has temperature protection (thermal cut-off)
  • power cable
  • pump power cables
  • single-module panel housing for boiler mounting or metal housing

Functions performed by the ST-37 controller:

  • CH pump control
  • DHW pump control
  • fan and screw auger or piston feeder control
  • possibility of connecting the ST-65 GSM module
  • possibility of connecting the ST-505 Ethernet module
  • possibility of connecting a room regulator with RS or traditional communication
  • possibility of controlling two valves using additional ST-61 v4 or ST-431N modules

ST-37 controller equipment:

  • LCD display
  • CH, DHW, feeder temperature sensor (protection)
  • has thermal protection (thermal cut-off)
  • panel housing for boiler mounting or in metal housing
Boiler type unit PROSAT WE 20 kW
Nominal heat output for coal kW 20
Range of heat output for coal kW 6.0-20
Boiler heating surface area m2 2.2
Boiler water capacity l 77
Heated area size m2 up to 200
Boiler class acc. to PN-EN 303-5: 2012   5
Efficiency % 89.0 - 90.0
Tank chamber capacity dm3 180
Burndown time at nominal power h 42
Max operating temperature (supply) °C 85
Min operating temperature (return) °C 60
Flue gas temperature nominal power °C 170 -185
Flue gas temperature minimum power °C 92 - 110
Maximum allowable working pressure Mpa 0.15
Test pressure Mpa 0.3
Required flue gas draft mbar 0.2
Flow resistance (10K) mbar 2.2 - 4.0
Minimum chimney opening cross-section cm2 230
Minimum chimney height m 6
Outlet nozzle diameter Ø mm 160
Boiler weight (+/- 5%) kg 380
Fuel: Hard coal   ecoal grade
type 31 or 31.1
granulation 5-25mm,
designation a
Supply and return nozzle diameter G 1 1/2"
Drain nozzle diameter G 1/2"
Power supply V/Hz ~230 V / 50 Hz / 6.3 A
Power consumption W 180
Energy consumption in standby mode W 11
Noise emission dB 45.5
Depth mm 945
Width mm 1190
Height mm 1260

 

Technical data

Boiler class (303-5:2012) 5
Power output 20 kW
Exhaust gas pipe diameter 160 mm
Weight 380 kg
Efficiency 90 %
Size of heated surface 200 m²
Ecodesign tak
Height 1260 mm
Width 1190 mm
Depth 945 mm
Minimum chimney section 230 cm²
Outlet and inlet size 1 1/2 G
Flue gas temperature 170 - 185 °C
Warranty 60 mies.
Power supply ~230 V / 50 Hz / 6,3 A
Min. chimney height 6 m
Required chimney draught 20 Pa
Silo volume 180 dm³
Max working pressure 1.5 bar
Exhaust pipe distance measured from the floor to its axis. 1151 mm
thickness of steel 6 mm
Boiler heating surface 2.2 m²
Slow combustion 42 h

Shipping costs The price does not include any possible payment costs

Shipping country:

Related products

Product reviews (0)

All reviews (positive and negative) are displayed. We don't verify that they come from customers who have purchased the product.

up
Shop is in view mode
View full version of the site
Sklep internetowy Shoper Premium